In a factory setting, it may be desirable to limit the access of the cMT X Series web browser.
We can do this by unchecking “Show navigation bar” and using the Control registers instead.

Control Word Codes:
1 – Go
2 – Reload
3 – Stop
4 – Back
5 – Forward
6 – Clear Cache
7 – Clear Cookies

For the favourites buttons, we’re using a “Combo Button” with 2 Actions

Action 1 – Write constant string with our URL

Action 2 – set the control word to “1” for “Go”

Repeat for shortcuts required.
As usual, we have a demo project for you to try out here.