TechTip: Using GETBIT in a Macro on Weintek HMI

Occasionally, you may need to read a bit or bits from a PLC or controller register if they are not directly accessible via the driver being used – an example of this could be a PLC status word where each bit represents the status of various PLC conditions, for example, “Battery Status” or “CPU Error” etc. Or it may be that you want to replicate some PLC logic that is otherwise inaccessible. The GETBIT macro instruction is very useful in these circumstances, enabling you to retrieve an individual bit and use that in conjunction with further logic such as an Continue reading TechTip: Using GETBIT in a Macro on Weintek HMI

New Supplier Announcement: Teknokol HMI Enclosures and Support Arms

Lamonde Automation is delighted to announce that we’ve signed a new supplier partnership with Teknokol, manufacturers of HMI enclosure systems which can be mounted directly to your machine, or the wall, or with custom-made support arms. Ergonomically designed and with IP65 protection, the enclosures have various depth options, and both the ECOline and TKP2000 series are modular, giving increased flexibility to suit your project. The enclosure front sheets are constructed from 2mm or 3mm aluminium, and Teknokol can provide custom-coloured couplings and covers upon request, as well as the processing of front sheets with laser cut-outs to accommodate any HMI, Continue reading New Supplier Announcement: Teknokol HMI Enclosures and Support Arms

TechTip: How to program Weintek HMI via Ethernet

This guide will show you how to connect a Weintek HMI to a PC via ethernet; to do this, we’ll be making sure that both screen and PC/laptop network adaptor are on the same subnet as each other.  Note: The illustrations in this Guide are based on an iE Series HMI. Other Series HMIs may appear a little different. For HMIs with dual ethernet, the IP addresses of the ports MUST be on different subnets.  Weintek System Settings1. On the Weintek HMI, tap the black arrow bottom right  2. To check if there is an IP address already set on the HMI, tap the Information button to show the settings for the device. In this case, we Continue reading TechTip: How to program Weintek HMI via Ethernet

New Feature Announcement – All Weintek HMI Now Support EasyAccess 2.0

The COVID-19 pandemic has brought new challenges and turned remote working into daily normality for many. As we face these changes, Weintek’s EasyAccess 2.0 remote solution is enabling users to overcome some of the challenges associated with remote working. To address these demands, Weintek is introducing EasyAccess 2.0 and VNC support to all their current HMI series. Additionally, for selected non-Ethernet HMI models, 4G dongle support will also be provided so that they can connect to the Internet to make use of EasyAccess 2.0. Since its launch 6 years ago, EasyAccess 2.0 has been offering a stable and reliable remote Continue reading New Feature Announcement – All Weintek HMI Now Support EasyAccess 2.0