Case Study: Board24 – Remote Monitoring & Control with CCTV and Fire Alarm Integration

We needed to find a way for the engineers on the Baler to see if the fans were running and to stop them remotely.  We also wanted to be able to see the status of the Baler from the fan end of the system without running over to check. Board24 is an FSC Certified manufacturer of recyclable corrugated sheetboard. They set high standards in terms of our product quality and environmentally friendly approach. They produce corrugated board which is 100% recyclable, 100% biodegradable and made from 90% recycled or recovered paper. We talked to Mark Crawford, Electronics Project Manager, about Continue reading Case Study: Board24 – Remote Monitoring & Control with CCTV and Fire Alarm Integration

TechTip: Connecting a Control Techniques Drive to a Weintek HMI Using Modbus RTU

This TechTip is about connecting a Control Techniques drive to a Weintek HMI using Modbus RTU. For the purposes of this TechTip, we’re using a CT Comander C300 drive fitted with an AI-485 option module. Drive SetupEither using the drive onboard menu via the keypad, or Control Techniques Connect, software, verify the communications settings (Address, Baud Rate, Data bits, Stop Bits, Parity) as these will need to be matched in your HMI project. Addressing FormatModbus Addressing format for Control Techniques drives is: 40000 + (menu number x 100) + (parameter number) The Weintek HMI does not require the 40000, so Continue reading TechTip: Connecting a Control Techniques Drive to a Weintek HMI Using Modbus RTU

Case study: Welland Medical Machine Data Capture

“We are very happy with the service from Lamonde and would recommend using this method of moving data. “ Welland Medical’s Story:We were looking for a method to move data from various production lines into our MySQL server. This would feed a front-end program and provide live OEE type data on large screens on the shop floor, but our machines have many different brands of PLCs fitted. We explored our options and received some quite expensive quotes. Duncan at Lamonde advised that we use Weintek’s cMT-SVR-100. We found this easy to use and can extract data from the majority of Continue reading Case study: Welland Medical Machine Data Capture

Solutions-Focused Case Studies

“That works beautifully, thanks!” MC, Board24 We love it when our clients give us feedback, and even more so when we’ve been able to collaborate with them to develop a creative solution to a particularly knotty problem. Over the coming months we’ll be publishing case studies and testimonials from our clients about specific solutions we’ve provided to some of the more unusual issues you’ve encountered. Check back regularly to read about our latest technical wizardry! If you’d like to provide feedback, or a specific issue case study, please email us at [email protected], or complete the form at https://www.lamonde.com/contact/, or call Continue reading Solutions-Focused Case Studies